Testing and diagnostics of power transformers brochure 4. Hence, it is essential to inspect and calibrate those instrument transformers at regular intervals. Testing procedures for hv voltage transformers testing procedures for hv voltage transformers photo credit. Testing potential transformers valence electrical training. Jul 24, 2015 the primary of voltage transformer is connected to power circuit between phase and ground. Hence potential transformer is that type transformer which protect from over voltage and also in earth fault protection. With our test systems, you can carry out a series of standard tests quickly, such as determining the magnetization characteristic, saturation behavior alffs, transformation ratio and its accuracy, polarity, load, winding resistance, withstand voltage. Worst case fault conditions are imposed at the output of the transformer shortcircuit conditions and separate overload conditions. The purchase, preparation, assembly, operation and maintenance of transformers. A test voltage is applied for a fixed period of time, usually. Transformer design to withstand switching must add strength 1. This test also performed as a routine test of transformer. Instrument transformer theory and testing steve hudson, pe engineering manager 10737 lexington drive knoxville, tn 37932 phone. Basics, maintenance, and diagnostics xi contents continued page 9.
The voltage transformer can be thought of as an electrical component rather than an electronic component. Power factor testing a twowinding transformer is conducted by. Connection on cpc100 will be same as the shown figure. A voltage transformer theory or potential transformer theory is just like a theory of general purpose step down transformer.
It evolved from the simple gonogo verdict into a sophisticated segment within transformer manufacturing. Pleasse send me pdf file of detailed transformers testing and earthing testing. In the case of an electronic ttr test set, a voltage usually 80 v ac is applied to the tested transformer hv winding. Testing will commence only after the equipment is completely installed as per approved method statement for the installation of the transformer and released for testing commissioning. Oct 11, 2015 oscillogram of dynamic shortcircuit test on 3phase 110. Insulation power factor testing of power transformers oleh w. The noload losses of a transformer are grouped in three main topics. Current transformers play an important role in the monitoring and protection of electrical power systems. Testing of high voltage cables manual horizon power. Transformer testing has developed considerably over the past years. The following sections of the ansineta standard for acceptance testing.
Section 7 of the ansineta standard for acceptance testing specifications for electrical power equipment and systems may be reproduced and used on a cut and paste basis for the particular type of equipment to be tested. Potential transformer testing ptvt valence electrical. So transformer ratio test is an essential type test of transformer. Repeat the test for the other phases and the other secondary cores. Standard accuracy class for metering service and corresponding limits of transformer correction factors accuracy class voltage transformers current transformers 90% to 100% rated voltage.
Testing of three phase power transformer ijireeice. Before conducting a transformer winding resistance test, it is important to observe all safety warnings and take proper precautions. Testing of power transformers 9 a 6 appendix 92 a 6. Testing procedures for hv voltage transformers include general inspection, insulation resistance, polarity and turns ration tests. P otential transformers pts are necessary to a power system for metering and protective relaying to convert higher system volt ages to lower control voltages that are practical from an equipment, operation, and safety perspective. Transformer routine test measurement of noload loss and.
Mar 31, 20 testing and commissioning instrumenttransformers free download as powerpoint presentation. Insulation resistance tester, microohmmeter, high voltage test set, digital voltmeter, cvt test set. Ac voltage is preferable to dc voltage for transformer testing because ac voltage simulates the internal stress that the transformers face during operating conditions. Testing of power transformers seems like a similar experience. Where indian standards do not exist for such categories of transformers, this part of is 2026 may still be applicable either as a whole or in part. Jun 01, 2015 potential transformer is a voltage stepdown transformer which reduces the voltage of a high voltage circuit to a lower level for the purpose of measurement. The three phase cylindrical synchronous generator 800 kva, 200 hz with special damper bars is most suitable to be used as a power supply for testing of singlephase and threephase power transformers. Power factor testing insulation power factor tests are used to measure dielectric losses, which relate the wetness, dryness or deterioration of transformer insulation. Just like the transformer used for stepping down purpose, potential transformer. The paper presents the method of selection, calculation and measurements of generator that is built into the new transformer test station. Test equipment within calibration date, tested and tagged. During the applied voltage test, the transformer winding reacts as a simple capacitive load.
The primary windings of the potential transformer are directly connected to the power circuit whose voltage is to be measured. Appliances like microwaves make use of high voltage transformers. Testing power transformers high voltage transformers are some of the most important and expensive pieces of equipment required for operating a power system. The power factor test determines the power loss of the transformers insulation system by measuring the power angle between an applied ac voltage and the resultant current. The purchase, preparation, assembly, operation and maintenance of transformers represent a large expense to the power system. This study focuses on the temperature of transformer winding, voltage ratio across hvlv, asymmetrical flux distribution in the core, insulation resistance of paper. Corona can be a problem when testing drytype transformers, so it is recommended that a power factor test be conducted at a lower voltage something below the corona inception point, and then at the normal test voltage. C electrical power from one voltage to another voltage keeping the frequency same by electromagnetic induction discover the worlds research 16.
Understanding insulation resistance testing pdf 0712 technical assistance 800 34391. Understanding transformer abnormal testing certifigroup. These are connected across or parallel to the line which is to be monitored. This includes power factor testing and other standard neta testing requirements. Dc dielectric withstand test voltage shall not exceed 100 percent of the ac rms test voltage. Transformers regulate the voltage in circuits, but in. Primary of this transformer is connected across the phase and ground. Common electrical tests on instrument transformers. Transformer field services transformer testing california. This transformer step down the voltage to a safe limit value which can be easily measured by the ordinary low voltage. Power factor is defined as the cosine of the phase angle between voltage. Teaching power transformer testing to undergraduates asee peer.
In this article, you will learn different types of transformer testing methods, test. Vancouver ieee transformers committee october 2427, 2016 5 impulse test concepts transformer switchinga current update. Cts are instrument transformers used for converting primary current into a reduced secondary current for use with meters, relays, control equipment and other instruments. Dc dielectric withstand test voltage shall not exceed 100 percent of the ac rms test voltage specified in ansi c57. Potential transformers pts or voltage transformers vts. Testing potential transformers by les warner pca valence and chris werstiuk valence electrical training services llc potential transformers pts are necessary to a power system for metering. A potential transformer is a conventional transformer. Testing potential transformers by les warner pca valence and chris werstiuk valence electrical training services llc potential transformers pts are necessary to a power system for metering and protective relaying to convert higher system voltages to lower control voltages that are more practical from. The current transformer is designed to connect in series with the line to transform the line current to the standard 5 amperes suitable for the meter or relay. Iwanusiw, consultant eltel industries, bangalore, india. The potential transformer may be defined as an instrument transformer used for the transformation of voltage from a higher value to the lower value. Apr 16, 2018 transformer abnormal testing is required on safety isolation transformers to insure that the transformer output remains below hazardous voltage levels during fault conditions in the secondary circuit.
Testing power transformers highvoltage transformers are some of the most important and expensive pieces of equipment required for operating a power system. Available from 25 kv to 800 kv for measurement, protection and control. The following tests are routinely conducted in the field on the transformer. Potential voltage transformers testing and precommissioning check potential voltage transformers can be broadly divided in to two type. Testing of power transformer measurement of impedance. Installation, testing and troubleshooting of transformers. Transformer pd and induced voltage withstand test system. The onoff impulse voltages are applied to each high voltage terminal sequentially. Voltage transformer testing swp page 3 of 19 standard work practice sp0508 ver 7 ergon energy corporation limited abn 50 087 646 062 if any risks cannot be managed or reduced to an. High voltage winding to low voltage winding and ground b. All materials and relevant documentation to this testing works shall be checked by the responsible personnel prior to the commencement of testing activities. Current transformers, inductive voltage transformers, capacitive voltage transformers, combined current voltage transformers and station service voltage transformers are designed to transform high current and high voltage levels down to low current and low voltage.
Because they pose a risk of shock, the transformer must be disconnected, and the capacitors bled, before testing. Cts are instrument transformers used for converting primary current into a reduced secondary current for use with meters, relays, control equipment and other instruments the importance of instrument transformer. Low voltage transformers operate many household appliances, from doorbells to airconditioning systems. Scribd is the worlds largest social reading and publishing site. The preference is that all large power transformers 1 mva be tested with ttr test set. Oct 21, 2014 testing on onload tap changers eight complete operating cycles with the transformer not energized, with 100% of rated aux supply voltage one complete operating cycle with transformer not energized, with 85% of the rated auxiliary supply voltage one complete operating cycle with transformer energized at the rated voltage and. Back to the basics potential transformer testing ptvt as test equipment becomes more sophisticated with better features and accuracy, we risk turning our field personnel into test set operators instead of skilled field service technicians. In this book we have laid down important aspects on transformer. Comprehensive electrical testing is offered to our customers. The transformer has been built to standard damage has not been sustained during transit or installation. It works on law mutual induction as in simple transformer. If the reactive power supplied by the generator g 1 is not sufficient when measuring large transformers, a capacitor bank c 1 is used to compensate part of the inductive reactive power taken by the transformer t 2. Partial discharge is a partial voltage breakdown within a series of insulating elements between two electrodes of different potential.
Standard for acceptance testing specifications for. Instrument transformer basic technical information and. Voltage transformer or potential transformer theory. Voltage transformers testing and commissioning guidelines. Power transformer testing procedures and schemes eep. Power factor testing nov2005 doble engineering company. Testing of current transformers, voltage transformers or auxiliary transformers internal to the power transformer are not included in this swp. Both factory and field testing are performed to verify the insulation integrity of substation transformers. Voltage transformers are used around the clock throughout the energy grid, and their life span can reach up to 40 years. The procedure of the transformer ratio test is simple. When the pt is withdrawn ensure that there is no longer any connection with the primary electrical system. Lv transformer electrical substation consists, therefore, of the set of devices dedicated to the transformation of the voltage supplied by the distribution network at medium voltage e. Potential transformers pts pts step down high voltages to the voltage. Transformer waveforms steadystate testing and performance of singlephase transformers report must be the students own work.
During that time, the effects of aging, regular operation, network faults. How to troubleshoot a lowvoltage transformer hunker. Partial discharge measurement should generally be the last dielectric test conducted on the transformer. Instrument transformers for metering purposes must have a high degree of accuracy up to class 0. By this way,the next impulse voltage waveform is applied. Transformer testing type tests and routine tests of.
If the low voltage test result is satisfactory, then the test can proceed at the normal test voltage. Ensure that all equipment to be tested is properly grounded and treat all high voltage. Transformers convert voltage for use in appliances. These can be of electromagnetic of capacitive voltage transformer type cvt. Power transformer testing transformers may be tested using ac or dc voltage. It is a good idea to remove all as a safety precaution to prevent backfeeding dangerous voltages into the system during testing. Verify correct operation of transformer withdrawal mechanism and grounding operation. During commissioning and operation it is essential that your power transformer is in good condition.
A low voltage transformer taps into a homes high voltage power supply and produces a safe, low voltage electrical feed. The voltampere rating of potential transformer is less than power transformer. Equipment required following equipment is necessary to perform testings. Northern michigan univer sity nmu is fortunate to have large power transformers for our undergraduate students to test. Feb 08, 2015 various routine test of power transformerpart1 february 8, 2015 26 comments. Voltage transformer or potential trans former theory.
This test usually known as no load test and involves inserting an alternating voltage in the high voltage winding of the transformer in each of its phases with low. Potential transformer pt definition the potential transformer may be defined as an instrument transformer used for the transformation of voltage from a higher value to the lower value. High voltage or stepup transformers turn lower voltages into higher intensities. All the routine tests shall be repeated dielectric test shall be at 75% transformer shall be untanked reactance measured after s. I cowrote an article for the neta world magazine in 20042005 that covers several different manual techniques for potential transformer testing that explains several lowtech solutions for potential transformer testing. Open as well as shorted terminals of nontested windings conclusions. Various influences can impact the expected lifetime. Making a wellinformed choice in equipment for transformer testing is an important step towards ultimately improving transformer life management decisions. The voltage of the supply generator is raised until the current has attained the required value 25100 % of the rated current according to the standard 4. Routine tests and type tests of transformers electrical4u.
The standard for maintenance testing specifications for electrical power equipment and. The basic principle of operation and construction of this transformer is similar to the standard power transformer. The test system is mainly designed for applied voltage tests. The complete guide to electrical insulation testing. A transformer basically is very simple static or stationary electromagnetic passive. So for ensuring proper performance of electrical power transformer, voltage and turn ratio test of transformer one of the important tests. Common electrical tests on instrument transformers omicron.
Working of potential transformer the electrical portal. Transformers experience power loss due to load resistance, which you can test with an ohmmeter by touching the meters red and black pins to opposite ends of the transformers. An electrical power transformer has to go through a number of transformer testing procedures for confirming its specifications and performances. Always troubleshoot a low voltage transformer before replacing it. The tap position of the transformer during test is determined according to test conditions. Before attempting to connect test equipment to a transformer.
The resistance of an alternating current ac transformer is held within the wires wound around its core. Insulation power factor testing of power transformers. The potential transformer is connected in parallel with the circuit. Iwanusiw, consultant eltel industries, bangalore, india resume this paper discusses the dissipation factor measurements that can be carried out. Potential transformers pts or voltage transformers. Synchronous generator for induced ac voltage test of single. Transformers are an electrical component that transmit electrical energy between at least two circuits.
1212 30 374 260 1473 200 206 965 1230 1313 102 1542 886 297 532 123 1156 790 1056 409 668 1005 602 127 574 496 329 1237 1190 538 1540 1604 1026 609 812 280 759 1308 1279 86 737 241 1039 453 1046 260